Teldat bintec RT1202 Manuale Utente Pagina 117

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 622
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 116
Fig. 41: System Management->Remote Authentication->TACACS+ ->New
The System Management->Remote Authentication->TACACS+ ->Newmenu consists of
the following fields:
Fields in the Basic Parameters menu.
Field Description
Authentication Type Displays which TACACS+ function is to be used. The value
cannot be changed.
Possible values:
/  -3": Here, you can define whether the
current TACACS+ server is to be used for login authentication
to your device.
Server IP Address Enter the IP address of the TACACS+ server that is to be re-
quested for login authentication.
TACACS+ Secret Enter the password to be used to authenticate and, if applic-
able, encrypt data exchange between the TACACS+ server and
the network access server (your device). The maximum length
of the entry is 32 characters.
Priority Assign a priority to the current TACACS+ server. The server
with the lowest value is the one used first for TACACS+ login
Teldat GmbH
10 System Management
bintec Rxxx2/RTxxx2 103
Vedere la pagina 116